FGH – Programmer

FGH' P256 PROGAMMER - FRONT

FGH-Mannings-Programmer-1

INTERNATIONAL DISTRIBUTION: SHIPS - NORTH AMERICA - 24 HOURS

Mining-Equipment-repair
Magnetic ceramic Pads-bright idea
Twin Heat Module-high quality
Twin heat module-user-friendly

The P256 Automatic, 6 Channel programmer / controller has been developed for use in conjunction with Stork’s Transformer Units, providing automatic temperature process control for up to six Transformer Unit output channels.

The P256 unit can operate temperatures both manually and automatically, depending on user requirements. In automatic mode, the channel controller will ensure that the control zone temperature closely follows the temperature rise, hold and fall period parameters programmed by the operator.

Programming and operation of the unit is kept uncomplicated and user friendly through the incorporation of microprocessor controlled programming, push-button operation and LCD display.

The LCD display provides visual indication of the running heat treatment program status and control zone output. In addition, individual neon lights indicate when a control zone contactor is energised.

The ‘Reversed Thermocouple Cut-out’ feature ensures the 6 Channel programmer / controller automatically cuts out the heater power when any control zone thermocouple input indicates a temperature below -40°C. This temperature level could indicate a reversed thermocouple fault

SPECIFICATIONS

Display: Graphic LCD panel 128 x 64 pixels
Display Backlight: Continuous yellow – green LED
Buttons: 8 off blue – green silicone rubber
Serial Interface: 2 off RS422/RS485
Supply: 95-253 V rms, 48-62 Hz, < 10 VA
Environment: Operating 0-60 ˚C, 5-95% rh non-condensing Storage minus 10-65 ˚C, 5-95% rh non-condensing
Sensors: Type K thermocouple to BS EN 60584-1 (others by special order)
Units: ˚C or ˚F
Resolution: Measurement 0.1 degree, Display 1.0 degree
Sampling: Every 0.735 seconds
Break detection: Up scale
Prop band: 10 ˚C (18 ˚F)
TP cycle time: 20 seconds
Hold band: 1, 2 or 3 times prop band
Hold type: Below only or above and below
Each controller has the following independent parameters:
Set point type: Manual or automatic
Manual set point: 0 – 1200˚C (2000˚F) in 1 degree increments
Auto s/p trim: +/- 50˚C (+/- 90˚F) in 1 degree increments
Auto s/p clamp: 0 - 1200˚C (2000˚F) in 1 degree increments
DIMENSIONS # Weight: 7kg
Case Dimensions:
Width: 26.5cm
Height: 22.5cm
CATALOG #
CERTIFICATIONS # CSA
DIMENSIONS # Width: 12.8" (325 mm)
Depth: 16.9" (430 mm)
Height: 10.02" (260 mm)
Weight: 28.7 Lbs (13.0 Kilo)

PROFILE

Heating rate: 1 (step) to 1000˚C per hour in 1 degree increments
Soak temperature: 0 to 1200˚C (2000˚F) in 1 degree increments
Soak time: 0 to 100 hours in 0.1 increments
Cooling rate: 0 (step) to 1000˚C per hour in 1 degree increments
End temperature 0 to 1200˚C (2000˚F) in 1 degree increments

CONSTRUCTION

Case Material: Painted mild steel as standard (stainless steel available on request)
Questions and Answers - Magnifying Glass on Words
FGH-P256-six channel-programmer-3

FGH P256 Programmer

DESCRIPTION

The panel mounting, P256 Automatic, 6 Channel programmer / controller has been developed for use in conjunction with Stork’s Transformer Units, providing automatic temperature process control for up to six Transformer Unit output channels.

GENERAL SPECIFCATION

The panel mounting, P256 Automatic, 6 Channel programmer / controller has been developed for use in conjunction with Stork’s Transformer Units, providing automatic temperature process control for up to six Transformer Unit output channels.

The P256 unit can operate temperatures both manually and automatically, depending on user requirements. In automatic mode, the channel controller will ensure that the control zone temperature closely follows the temperature rise, hold and fall period parameters programmed by the operator.

Programming and operation of the unit is kept uncomplicated and user friendly through the incorporation of microprocessor controlled programming, push-button operation and LCD display. The LCD display provides visual indication of the running heat treatment program status and control zone output. In addition, individual neon lights indicate when a control zone contactor is energised.

The ‘Reversed Thermocouple Cut-out’ feature ensures the 6 Channel programmer / controller automatically cuts out the heater power when any control zone thermocouple input indicates a temperature below -40°C. This

CONTROLLERS

Sensors: Type K thermocouple to BS EN 60584-1 (others by special order)
Units: ˚C or ˚F
Resolution: Measurement 0.1 degree, Display 1.0 degree
Sampling: Every 0.735 seconds
Break detection: Up scale
Prop band: 10 ˚C (18 ˚F)
TP cycle time: 20 seconds
Hold band: 1, 2 or 3 times prop band
Hold type: Below only or above and below
Each controller has the following independent parameters:
Set point type: Manual or automatic
Manual set point: 0 – 1200˚C (2000˚F) in 1 degree increments
Auto s/p trim: +/- 50˚C (+/- 90˚F) in 1 degree increments

PROFILE

Heating rate: 1 (step) to 1000˚C per hour in 1 degree increments
Soak temperature: 0 to 1200˚C (2000˚F) in 1 degree increments
Soak time: 0 to 100 hours in 0.1 increments
Cooling rate: 0 (step) to 1000˚C per hour in 1 degree increments
End temperature: 0 to 1200˚C (2000˚F) in 1 degree increments
Twin Heat module -CSA

Canadian Standards Association

is a standards organization which develops standards in 57 areas. CSA publishes standards in print and electronic form, and provides training and advisory services. CSA is composed of representatives from industry, government, and consumer groups.

All of the Canadian provinces have adopted the CSA electrical standards, which means that certification is mandatory for all electrical products

Warranty

warranty

Warranty and Services:

First Year:
– 100 percent of parts & 100 percent labor is covered by Innovative Heat Treatment Inc.

Second Year
– 50 percent of parts & 100 percent labor is covered by Innovative Heat Treatment Inc.

Third Year
– 50 percent of parts & 100 percent labor is covered by Innovative Heat Treatment Inc.

Related Products

Related Products

Related Products

Related Products

Related Products